If you were Registered and logged in, you could reply and use other advanced thread options
|
Posted by Kay Lancaster on February 7, 2006, 5:42 pm
http://www.cpsc.gov/cpscpub/prerel/prhtml06/06082.html
|
|
Posted by on February 7, 2006, 10:11 pm
Kay Lancaster wrote:
show/hide quoted text
> http://www.cpsc.gov/cpscpub/prerel/prhtml06/06082.html
About 4 or 5 years ago or so Viking had a recall on one of their models
of sewing machines, also priced around $5,000. It, too, was an
electrical problem. If I remember correctly the recall was a danger of
electrocution.
Geez.
|
|
Posted by on February 7, 2006, 10:15 pm
Kay Lancaster wrote:
show/hide quoted text
> http://www.cpsc.gov/cpscpub/prerel/prhtml06/06082.html
I went back and re-read the recall and I'm wondering if this is the
original recall from several years ago and they thought best to make it
public again?? Interesting!
Anyway, thanks!
|
|
Posted by Kay Lancaster on February 8, 2006, 5:42 am
On 7 Feb 2006 19:15:42 -0800, itsjoannotjoann@webtv.net wrote:
show/hide quoted text
>
> Kay Lancaster wrote:
>> http://www.cpsc.gov/cpscpub/prerel/prhtml06/06082.html
>
>
> I went back and re-read the recall and I'm wondering if this is the
> original recall from several years ago and they thought best to make it
> public again?? Interesting!
The 1/1+ machines seem to be snakebit... CPSC announcements are:
Dec 1999: Designer 1+: defective power cord/transformer connection; shock risk
11,000 machines
Oct 2002: Designer 1: power supply smoking/catching fire
1,100 machines
Feb 2006: Designer 1: power supply arcing; 3 fires
5,500 machines
|
|
Posted by Welmoed Sisson on February 8, 2006, 7:48 am
show/hide quoted text
>On 7 Feb 2006 19:15:42 -0800, itsjoannotjoann@webtv.net wrote:
>>
>> Kay Lancaster wrote:
>>> http://www.cpsc.gov/cpscpub/prerel/prhtml06/06082.html
>>
>>
>> I went back and re-read the recall and I'm wondering if this is the
>> original recall from several years ago and they thought best to make it
>> public again?? Interesting!
>The 1/1+ machines seem to be snakebit... CPSC announcements are:
>Dec 1999: Designer 1+: defective power cord/transformer connection; shock risk
> 11,000 machines
>Oct 2002: Designer 1: power supply smoking/catching fire
> 1,100 machines
>Feb 2006: Designer 1: power supply arcing; 3 fires
> 5,500 machines
Kay,
The 1+ is different than the Designer 1 (The 1+ was the Viking TOL
before the Designer 1 came out). I don't think the 1+ has ever had a
recall.
--Welmoed
|
Page 1 of 2 1 2 > last >>
| Similar Threads | Posted | | Viking Safety Recall! | February 7, 2006, 5:15 pm |
| FA: Husqvarna Viking Designer SE | September 1, 2007, 9:48 am |
| New Designer - Fabri'kate | October 22, 2006, 2:53 pm |
| Designer Sarees | January 4, 2008, 5:41 am |
| hasquvarna viking 190 | March 20, 2006, 6:53 pm |
| Buying Husqvarna Viking E10 | December 2, 2006, 1:41 am |
| Husqvarna Viking Rose | July 25, 2007, 12:03 pm |
| What would you do to embellish a handbag, to give it a more designer look? | December 22, 2009, 11:53 am |
|
|